Digital Dosing Units
1
SDD Digital Dosing Units
Part Number: 882.00276.00
Bulletin Number: BF3-600
Effective: 12/01/05
Write Down Your Serial Numbers Here For Future Reference:
_________________________ _________________________
_________________________ _________________________
_________________________ _________________________
We are committed to a continuing program of product improvement.
Specifications, appearance, and dimensions described in this manual are subject to change
without notice.
DCN No. ____________
© Copyright 2005
All rights reserved.
Przeglądanie stron 0
1 2 3 4 5 6 ... 66 67

Podsumowanie treści

Strona 1 - SDD Digital Dosing Units

Digital Dosing Units 1 SDD Digital Dosing Units Part Number: 882.00276.00 Bulletin Number: BF3-600 Effective: 12/01/05 Write Do

Strona 2

Digital Dosing Units 93. Press Input to display #2, “Shot size of current mold”. Using arrow keys, set the total shot size (parts and runners) of t

Strona 3 - Table of Contents

Digital Dosing Units 106. Repeat step #19 four more times, each time entering the new weight from the scale into the controller using the arrow keys.

Strona 4 - Section 1: Introduction

Digital Dosing Units 11Section 3: Initial Installation And Operation 3.1 Initial Installation Direction of Material FlowHopper PieceProcessingMachin

Strona 5

Digital Dosing Units 12be exposed to extreme heat (maximum temperature 45°C or 115°F) or excessive moisture. 4. Electrical connection to process mach

Strona 6 - 1.1 Controller

Digital Dosing Units 13NOTE: Zero input corresponds to zero screw speed and no additive dosing. Maximum input corresponds to maximum screw speed. N

Strona 7 - 1.2 Keys and Symbols

Digital Dosing Units 14• Recipe parameters are different for Injection Molding, Extrusion-Constant, and Extrusion-Proportional operation. See each i

Strona 8 - Symbols

Digital Dosing Units 15• Enter the additive percentage by using the Arrow Keys . (The range of values that can be entered is 0.01% to 50.00%.

Strona 9 - Section 2: Quick Start-up

Digital Dosing Units 16this value during operation. The range of values that can be entered in this field is 00.50 to 99.99 seconds. Step 4:

Strona 10 - Digital Dosing Units

Digital Dosing Units 17• After “5” flashes on the display, a number in the format xxx.xx will come up on the display. • Enter the maintained runnin

Strona 11

Digital Dosing Units 181. Pressing again will first display the number “18” and then will display the total throughput in kilograms (totalizer). O

Strona 12 - 3.1 Initial Installation

Please note that our address and phone information has changed. Please reference this page for updated contact information. These manuals are obsolet

Strona 13

Digital Dosing Units 19light on the controller during screw recovery. The disc symbol will light when the Digital Dosing unit is dosing material.

Strona 14 - 3.2 Initial Operation

Digital Dosing Units 20 • Press once. • The symbol will flash. • After “1” flashes on the screen, a number in the format xxx.xx will come

Strona 15 - 3.3 Injection Molding

Digital Dosing Units 21 • Press a third time. • The machine displays a flashing , “g” or “lb” and a number “4”flashes on the display (because thi

Strona 16

Digital Dosing Units 22 Step 5: 6. Press again. 7. The number “18” will be displayed before the total throughput in kg is displayed. Operatio

Strona 17

Digital Dosing Units 23NOTE: See Appendix A, Troubleshooting, for information on problems or errors encountered and their resolution. 3.5 Extrusion P

Strona 18

Digital Dosing Units 24Step 2: • Press again. • The machine displays a flashing “g” or “lb”, a flashing “min” and . • After “2” flashes q

Strona 19 - Operation-Injection Molding

Digital Dosing Units 25Step 4: 1. Press a fourth time. 2. The machine displays a flashing and “g”. 3. After “4” flashes quickly on the

Strona 20 - 3.4 Extrusion Constant

Digital Dosing Units 262. Place the Digital Dosing unit into operation by pressing the Run key ( ). The green LED will light when the unit is ready

Strona 21

Digital Dosing Units 27Determining the Calibration Weight Step 1: • To start the calibration process, press the calibration key. Step 2: •

Strona 22

Digital Dosing Units 28• The disc will rotate one full revolution. After the disc has stopped rotating, a number in the format “xx.xx” will appear o

Strona 23

Digital Dosing Units 2Table of Contents SECTION 1: INTRODUCTION …………….……………………….………...3 1.1 Controller. ...

Strona 24 - 3.5 Extrusion Proportional

Digital Dosing Units 29• Pressing the stop button will stop proportioning and not accept the calibration weight. • Pressing the calibration button

Strona 25

Digital Dosing Units 30Section 4: Advanced Operations/ Control Functions 4.1 Recipe Storage And Recall A maximum of ten (10) recipes can be stored a

Strona 26

Digital Dosing Units 31 • Press and hold the button until the totalizer display returns to the screen. • The recipe is now stored under the sele

Strona 27 - 3.6 Calibration

Digital Dosing Units 32 • Press and hold until the totalizer appears on the screen. • The recipe is now active and can be run or edited. NOTE:

Strona 28

Digital Dosing Units 33Alarms Several alarm options are available for the Digital Dosing feeder. The standard unit comes with a flashing alarm symbol

Strona 29

Digital Dosing Units 34Mixer An optional mixer is available that can be mounted under the Digital Dosing unit. The mixer is used to help distribute f

Strona 30

Digital Dosing Units 35Figure Section 5: Maintenance 5.1 Maintenance Intervals Daily: Check warning signs on equipment for good legibility and co

Strona 31 - Recipe Storage

Digital Dosing Units 36 6. Remove the dosing unit from the dosing motor. 7. Remove the cover from the connecting piece (D). 8. Loosen the two scre

Strona 32 - Recipe Recall

Digital Dosing Units 375. Remove the dosing hopper from the dosing unit. 6. Dismantle the dosing unit and remove the scraper (D). 7. Loosen the two

Strona 33 - 4.4 Optional Equipment

Digital Dosing Units 385.4 Changing the Dosing Disc in the Digital Dosing Dosing Station Removing the Dosing Disc 1. Empty the dosing station. 2.

Strona 34 - Level Probes

Digital Dosing Units 3 Section 1: Introduction This User’s Manual is intended for use with the Digital Dosing Additive Feeder. The feeder precisely

Strona 35 - EUROMAP E17 Interface

Digital Dosing Units 39 Installing Different Types of Dosing Discs Dosing discs of the same type may be exchanged for each other without any problems.

Strona 36 - Section 5: Maintenance

Digital Dosing Units 409. Install the dosing container along with the dosing hopper on the dosing housing (pay attention to the guide pins). 10. Moun

Strona 37 - Installing the scraper

Digital Dosing Units 41 17. Install the dosing container along with the dosing hopper on the dosing housing (pay attention to the guide pins). 18.

Strona 38

Digital Dosing Units 42 6. Never try to repair a defective fuse. 7. Open the screws (A) and remove the lid (B). 8. Remove the blind lid (C) and o

Strona 39 - Installing the Dosing Disc

Digital Dosing Units 43Appendix A: Troubleshooting During setup and use of the Digital Dosing Additive Feeder, personnel may experience difficulties.

Strona 40

Digital Dosing Units 44ERROR CODES Code Definition Possible Reason/Solution A001 Strap “safety switch” is missing. Manufacturer Service. A002 T

Strona 41

Digital Dosing Units 45A.3 Determining the Software Setup Factor The Digital Dosing control unit is configured via a Software Setup Factor (binary c

Strona 42 - 5.8 Replacing Fuses

Digital Dosing Units 46 Disc RPM( Additive - %) x (Total Extruder Throughput - lb / hr) 13.22 x (Disc Calibration Weight - g)= Recipe Limitat

Strona 43

Digital Dosing Units 47Appendix B: Basic Parameter Settings Extrusion Mode: You need an extruder signal that is proportional to the extruder speed t

Strona 44 - Appendix A: Troubleshooting

Digital Dosing Units 48If a current signal is available (0 - 20 mA) calculate the frequency output of the extruder for the lower / upper working area

Strona 45 - ERROR CODES

Digital Dosing Units 4 Figure 2. 2 Station Digital Dosing Unit QUI CK START PAGES HAVE BLUE BORDER

Strona 46 - A.4 Recipe Formulas

Digital Dosing Units 49Alarm output is switched in case of power failure . . . . . . . . . . . 512 ___ Extrusion mode . . . . . . . . .

Strona 47 - Recipe Limitations Extrusion

Digital Dosing Units 50Totalizer displayed in lb (kg default) . . . . . . . . . . . . . . . . . . . . . . . . . 16 ___ Shotweight up to 6.5 kg .

Strona 48

Digital Dosing Units 51Basic Parameter Settings

Strona 49

Digital Dosing Units 52

Strona 50 - Injection Molding:

Digital Dosing Units 53

Strona 51

54Appendix C: Disc Dosing Factors And Equipment Drawings And Parts Numbers Disc Dosing Factor Table 1: Disc Guide Disc Disc Nomenclature Used in

Strona 52 - Basic Parameter Settings

55 D30-051725 Default Calibration # 7.30 g/rev 051725 # of Holes Diameter Disc Thickness 0.2 Rev./min 6.4

Strona 53

56DT30-102025 Sure-Shot disc No Picture Default Calibration # 33.00 g/rev P102025 # of Holes Diameter Disc Thickne

Strona 54

57 DP30 050940 Default Calibration # 15.00 g/rev P050940 # of Holes Diameter Disc Thickness 0.2 Rev./min 6.4Rev./min (6.

Strona 55 - Numbers

58 Specification Sheet DIGITAL DOSING UNIT TECHNICAL PARAMETERS Disc Dosing Factor Table 2 Maximum Number of Feed Stations One (1) for Granule P

Strona 56

Digital Dosing Units 51.1 Controller The Digital Dosing additive feeder consists of a controller, dosing motor, and feeder(s). The controller is use

Strona 57

59 Digital Dosing unit parameter setup 7-14 Bison - Black motor Bauer - Blue

Strona 59 - Specification Sheet

61Station 1 Digital Dosing Unit SIDE VIEW TOP VIEW

Strona 60

62Station 2 Digital Dosing Unit SIDE VIEW TOP VIEW

Strona 61

63 Dosing Unit Electrical Schematic Chart Drawing No. Description of Drawing VoltageCT102020 C150 CONTROLLER INJECTION 110 CT102021 C150 CONTROLLE

Strona 62 - TOP VIEW

64Appendix D: Spare Parts List Dosing Disc/Shear Order Numbers Dosing disc 72 chambers ID 100562 49 chambers ID 21710 25 chambers ID 21711 18 ch

Strona 63

65-Notes-

Strona 64

66Technical Assistance Parts Department Call toll-free 7am–5pm CST [800] 423-3183 or call [630] 595-1060, Fax [630] 475-7005 The ACS Customer Service

Strona 65

Digital Dosing Units 6 1.2 Keys and Symbols Recipe Storage/Recall: For saving, recalling or modifying recipes. Stop: Stops the continuous operati

Strona 66

Digital Dosing Units 7Symbols Lights when the run signal from the process machine is received by the Digital Dosing controller. During operation,

Strona 67 - Technical Assistance

Digital Dosing Units 8Section 2: Quick Start-up Quick Start is intended to help you in starting up your Digital Dosing feeder quickly and easily. Pl

Komentarze do niniejszej Instrukcji

Brak uwag